!Template ver: 2015-04-30 ---------------------------------------------------------------------------------------------------------- Company Invited: Fire Suppression Services (Salt Lake City, UT) CALLOUT A Due Date: 08-31-2018 11:00 AM Manager: Big-D Phone: Scott Mazerolle & Creggan Wagstaff (435) 255-8418 cwagstaff@big-d.com Architect: ARCHITECTURAL NEXUS, Inc archnexus.com Project #18065 SALT LAKE CITY 2505 East Parleys Way Salt Lake City, Utah 84109 T 801.924.5000 Julie Berreth 801.924.5039 AHJ/FM: NFPA/IFC 2015 OWNER: National Ability Center Kevin Stickelman 435.649.3991 PERMIT: eg: BLD201Y-##### Assembly Group A-3 per section 304 of the IBC: assembly use intended for worship, recreation or amusement. expansion is Type V-B, as defined in the International Building Code (IBC). As a result, most of the components of the building are not generally required to be fireresistance- rated (per Table 601). See also the implications under “Height and Area Limitations” in specs folder. PROJECT STATUS: (Awarded) (Open to Bid) START DATE: PROJECT LOCATION: 1000 Ability Way Park City, UT 84060 PARCEL INFORMATION: Sales Taxable: NO NO NO NO NO NO Note: TU = Tilt Up TI = Tenant Improvement DESCRIPTION 8,355 SF 7.000' ASL Winter -7. degF. Fire riser room will include a 2 KW electric unit heater. and read p 8 of 18065 NAC specs Height and Area Limitations Under the 2015 IBC, a single-story, sprinklered, Type V-B, Group A-3 building has a tabular allowable area of 24,000 s.f. Even without consideration for an area increase due to frontage, we are well within the allowable area. The maximum allowable height is 2 stories above grade plane and has a limit of 60 feet. The new building is planned to be 1 story, and the tallest portion of the building is shown as 28’-3”. Fire Riser Room VICTAULIC & grooved couplings ok. Center on tile Fire riser room will include a 2 KW electric unit heater. See Specs Folder Page 15 See Specs Folder Page 15 See Specs Folder Page 15 See Specs Folder Page 15 See Specs Folder Page 15 See Specs Folder Page 15 See Specs Folder Page 15 See Specs Folder Page 15 See Specs Folder Page 15 See Specs Folder Page 15 See Specs Folder Page 15 See Specs Folder Page 15 See Specs Folder Page 15 See Specs Folder Page 15 See Specs Folder Page 15 See Specs Folder Page 15 See Specs Folder Page 15 See Specs Folder Page 15 AND: a noti of .... MEETINGS YOU MUST/MAY ATTEND in order to BID!!!! ---------------------------------------------------------------------------------------------------------- CALL OUT B Divisions that I require an answer/bid from BY RETURN email please. the div list here will be annotated accordingly [options are: BID/NoBid] Div-10 Fire Protection Specialties REQUIRED 10lb @43 + Tag @ $6 + Deliver@ $6 then markup at 30% Div-21 Fire Suppression Sprinklers etc REQUIRED Div-28 Life Safety Fire Alarms REQUIRED Read p 3 of 4 of specs (19 in their pdf) Div-31-33 Ground No Answer Sometimes I do NOT know what divs are required. you will have to check, and advise me if you notice, & I shall update the !Notes.txt here. ---------------------------------------------------------------------------------------------------------- CALLOUT C for you to observe the PlanRoom Folders that have data. e.g.: Addenda, Plans, Pics, Docs you will need to check folders that may be added to from time to time, i won't always advise you. //====================================================================== CALLOUT Z TAKE NOTE: - Sprink Inspectors; - Hood Installer, - Hood Cleaner - Alarm Manager - Extinguisher & Cabinet Group be Advised: ALL FIRE SUPPRESSION DIVISIONS ARE SUBJECT TO: DIVISION 23 SECTION 23 05 50 - OPERATIONS & MAINTENANCE MANUALS; Identification of Pipe-Work; - Training of Maint Staff and other personel; Warranty. This is a CONDITION of the A201 Contract & Scope on ALL CONTRACTS. I don't want to hear about it! We MUST Supply/Deliver to the Customer: - Hands-on & Lecture TRAINING AND - we invite the local Fire Crew out to view the fittings and FDC & Riser Location. - We MUST Supply: - a Training Manual (Three Hard Copies) AND - Full-Size AS-BUILT drawings. (Three Hard Copies) - All Installation, Operation, Instruction & Repair Manuals for the installed equipment. - And all also cut onto a CD/DVD size disc. (Three Copies) Arun (Mr.) Compliance Manager 2016-Oct-17 //======================================================================