!Template ver: 11:47 2018-01-10 Mods: 2015-04-30 ---------------------------------------------------------------------------------------------------------- Company Invited: Fire Suppression Services (Salt Lake City, UT) CALLOUT A Due Date: Manager: Phone: (801) 592-1979 Mechanical: Architect: AHJ/FM: Brett Larson OWNER: Tenant: Alex Loveless (801) 592-1979 endgrain@live.com PERMIT: eg: BLD201Y-##### PROJECT STATUS: (Open to Bid) START DATE: PROJECT LOCATION: 1092 North Industrial Park Drive Orem, UT 84057 PARCEL INFORMATION: Sales Taxable: YES/NO Note: TU = Tilt Up TI = Tenant Improvement DESCRIPTION Cabinet shop wood. see PICS folder in PlanRoom. Here is some information so that you may be able to put together a quote for sprinklers of his building. 1 - Pictures a - Looking North below storage mezzanine b - Looking North below storage mezzanine c - Looking at NW corner of space, possible riser location d - Looking south from NW corner out in wood shop up to roof, Z purlins and insulation e - Looking SE from NW corner out in the wood shop up to roof and storage mezzanine f - At from entry looking North at entry and offices Engrain Wood Design building footprint - +/-6,800 sq. ft. (Building foot print +/-13,800 sq. ft.) Total sprinklers estimated upright/ pendent throughout the space, 48 SSU at the roof 18 SSU below the mezzanine 9 SSP at Entry and offices 74 SSU/SSP Total Estimated 4" riser, 6" underground from Industrial Road +/- 75 ft from connection to riser location. Estimated design cost - $4,000.00 Bret Larsen has also advised him that he can add fire wall to divide the space into area less than 2,500 sq. ft. that would eliminate the need for sprinklers. Hope this helps and gives you information you need for an estimate for Alex. AND: a noti of .... MEETINGS YOU MUST/MAY ATTEND in order to BID!!!! ---------------------------------------------------------------------------------------------------------- CALL OUT B Divisions that I require an answer/bid from BY RETURN email please. the div list here will be annotated accordingly [options are: BID/NoBid] Div-10 Fire Protection Specialties REQUIRED Div-21 Fire Suppression Sprinklers etc REQUIRED Div-28 Life Safety Fire Alarms No Answer REQUIRED Div-31-33 Ground REQUIRED 70 ft from curb to bldg. Sometimes I do NOT know what divs are required. you will have to check, and advise me if you notice, & I shall update the !Notes.txt here. ---------------------------------------------------------------------------------------------------------- CALLOUT C for you to observe the PlanRoom Folders that have data. e.g.: Addenda, Plans, Pics, Docs you will need to check folders that may be added to from time to time, i won't always advise you. //====================================================================== CALLOUT Z TAKE NOTE: - Sprink Inspectors; - Hood Installer, - Hood Cleaner - Alarm Manager - Extinguisher & Cabinet Group be Advised: ALL FIRE SUPPRESSION DIVISIONS ARE SUBJECT TO: DIVISION 23 SECTION 23 05 50 - OPERATIONS & MAINTENANCE MANUALS; Identification of Pipe-Work; - Training of Maint Staff and other personel; Warranty. This is a CONDITION of the A201 Contract & Scope on ALL CONTRACTS. I don't want to hear about it! We MUST Supply/Deliver to the Customer: - Hands-on & Lecture TRAINING AND - we invite the local Fire Crew out to view the fittings and FDC & Riser Location. - We MUST Supply: - a Training Manual (Three Hard Copies) AND - Full-Size AS-BUILT drawings. (Three Hard Copies) - All Installation, Operation, Instruction & Repair Manuals for the installed equipment. - And all also cut onto a CD/DVD size disc. (Three Copies) Arun (Mr.) Compliance Manager 2016-Oct-17 //======================================================================