Heritage Gardens 10:49 AM 10/1/2019 No further progress. They gave him a floor plan which was all he asked for. 3:03 PM 9/19/2019 Sprink design 3,100 HydoCalcs 700 Supply analysis $550 Site visit 3 all pipe inside insulation 2:48 PM 9/17/2019 Architect: Hang tight until they can sort out 'issues' 4:14 PM 9/16/2019 According Jason Ausdale. Zoning rules do not allow a second level. Assisted Living Facility NFPA 13 10:35 AM 9/11/2019 No hydrants. Spoke with Marci at Springville PU. Requested a Flow Calc (801) 491-2780 mclark@springville.org https://www.springville.org/public-works/water/staff-water/ 09:48 PM 9/6/2019 Spoke with Architect. Layton Davis (801) 487-0715 Project# 19-058 Knows us from Arts Place. Architect has changed Co. name. Archetect was engaged by previous Owner: Gerrard Osmond. Now just trying to help new owner Ted. Will get us floor and reflected. Says will 'insulate' to roof. 12:48 PM 9/5/2019 Spoke with AHJ T Mills Showed him around the web section. May re-visit Fire Permit 10:36 AM 9/3/2019 Spoke with AHJ Mills, call him Thursd to review pics etc. At funeral today. 2:37 PM 8/30/2019 Bill & Justin on site. Stop work order is posted on the window, dated July-2017 No Permit is visible. Kimco tags Dry-Chem HE0621 Head box has wrench & TY3531 155 heads Victaulic valve is 4" x 114, 3WW No sign on riser room door. Riser IS supplying the sprinks via a Zurn PRV in side then via pvc to a Zurn 375 RP outside. FACP is Mountain West Sept-2018 with 7788F internent AES Pull station for hood suppression is not by an exit/egress route TAGs: H100411 & HE106211 (Kimco) Cardboard in ceiling is covering the makeup air duct 1:51 PM 8/30/2019 Rafael believes the riser stack supplies the lawn irrigation sprinklers. AF loop was part of origianal install 1995, however they have now tied in to it & it has been extended in this build period. Room 201 labeled New Storage, is going to be an apartment. (Residential) 1:25 PM 8/29/2019 From Bill Gubler (FSS): Welds are covered up, Wrap-ped! No record of 'Inspection' before or after wrap. End-of-line pull statation, and Kimco have tagged the hood system! (Kimco Tag is on pull station) Rafael confirms: Kimco TAG on PullStn. odd, KimCo does not have a license on UT SM site, for Chem Suppression. (He has it for Sprinks) Ren Zeeman (801) 881-1888, O: (801) 221-1888 Bruce Christensen, President Kim B Montague 12:12 PM 8/29/2019 Bill Gubler and RCastillo at site 11:46 PM 8/29/2019 Spoke with FSS Inspector Heath. See his report in planroom. Lost his laptop, cannot locate pics. I Asked SFPS to photo the BFP. 11:00 PM 8/29/2019 Just got off phone with Architect Layton Davis. Spoke with Paul at Layton Davis Architects.​ They met with city !yesterday!. Permit is still in progress.​ Hence the Progress Set.​ Call John Shepherd (801) 487-0715 on Tues 03 next.​ General Contractor may be Utah HomeSmith? per Holly Gill of Springhill City Plan from Architects is in Review 19-398 9:55 AM 8/29/2019 SFPS is to attend site, today in 60 mins 8:45 AM 8/29/2019 Troy Mills UT State fire marshal: Has issued a cease-&-desist to Tyler Thomas Lemmons- of Lemmons Fire Protection LLC: 2293 Bridle Oak Dr, South Jordan, UT 84095 operationg without any Fire Licenses. (NB: Business license expired) State Fire Marshal wants: Full plan set submitted for permitting to City. Then Fire set submitted for Permit Remove antifreeze from system and connect to a full wet/dry system Second storey rooms need structural design calcs against Occupancy class per City Building Dept Code requirements. Submittal for these 'rooms' for what 'class'. It needs a floor. Kitchen Hood duct work is going nowhere? Neeed inspect openings, maybe? Alarms what is going on with that? Troy says Ted Woodger's brother is Troys brother-in-law. Troy would meet with Rafael next wed, at site. Troy says Rafael can call him. 9:41 AM 8/29/2019 Rafael says do it on 11th? 9:42 AM 8/29/2019 !Template ver: 11:47 2018-01-10 Mods: 2015-04-30 ---------------------------------------------------------------------------------------------------------- Company Invited: Fire Suppression Services (Salt Lake City, UT) CALLOUT A Due Date: ASAP Manager: Phone: Mechanical/Struct: CKR Engineers 343792 Chad Kohler Project#: 19-069 2019-02-20 Architect: Layton Davis (801) 487-0715 Project# 19-058 Colton is who I talk with. It is John Davis who did the Design AHJ/FM: UT State Fire Marshall Troy Mills 801 556-4154 Local FM is Calvin Christiansen: cchristiansen@springville.org No Jurisdiction, tho' OWNER: Ted or Rebecca Woodger (801) 891-2259 woodger3714@gmail.com rebeccavomdorp@gmail.com https://hgspringville.com/ owned the Riviera Apts in Provo. PERMIT: BLD2018-0398 Springville Review number Repair & replace roof section; Add kitchen room; Demolition of old roof structure & walls to repair fire system & shore-up roof area. Replace swamp cooler and extend hood fan. PROJECT STATUS: (Open to Bid) START DATE: PROJECT LOCATION: Heritage Gardens Care Center 321 East 800 South Springville UT 84663-2450 (801) 489-3344 PARCEL INFORMATION: Utah County 260320103 Sales Taxable: YES SRC $15 applied Note: TI = Tenant Improvement DESCRIPTION Assisted living facility. Therefore US State Fire Marshal. OCC=30. 20 rooms AND: a noti of .... MEETINGS YOU MUST/MAY ATTEND in order to BID!!!! ---------------------------------------------------------------------------------------------------------- CALL OUT B Divisions that I require an answer/bid from BY RETURN email please. the div list here will be annotated accordingly [options are: BID/NoBid] Div-10 Fire Protection Specialties REQUIRED Div-21 Chem Suppression and Ducts REQUIRED Div-21 Fire Suppression Sprinklers etc REQUIRED Div-28 Life Safety Fire Alarms REQUIRED SK by Honeywell? Div-31-33 Ground No Answer Sometimes I do NOT know what divs are required. you will have to check, and advise me if you notice, & I shall update the !Notes.txt here. ----------------------------------------------------------------------- CALLOUT C for you to observe the PlanRoom Folders that have data. e.g.: Addenda, Plans, Pics, Docs you will need to check folders that may be added to from time to time, i won't always advise you. //====================================================================== CALLOUT Z TAKE NOTE: - Sprink Inspectors; - Hood Installer, - Hood Cleaner - Alarm Manager - Extinguisher & Cabinet Group be Advised: ALL FIRE SUPPRESSION DIVISIONS ARE SUBJECT TO: DIVISION 23 SECTION 23 05 50 - OPERATIONS & MAINTENANCE MANUALS; Identification of Pipe-Work; - Training of Maint Staff and other personel; Warranty. This is a CONDITION of the A201 Contract & Scope on ALL CONTRACTS. I don't want to hear about it! We MUST Supply/Deliver to the Customer: - Hands-on & Lecture TRAINING AND - we invite the local Fire Crew out to view the fittings and FDC & Riser Location. - We MUST Supply: - a Training Manual (Three Hard Copies) AND - Full-Size AS-BUILT drawings. (Three Hard Copies) - All Installation, Operation, Instruction & Repair Manuals for the installed equipment. - And all also cut onto a CD/DVD size disc. (Three Copies) Arun (Mr.) Compliance Manager 2016-Oct-17 //======================================================================