!Template ver: 11:47 2018-01-10 Mods: 2015-04-30 ---------------------------------------------------------------------------------------------------------- Company Invited: Fire Suppression Services (Salt Lake City, UT) CALLOUT A Due Date: Manager: Phone: Mechanical: Architect: Josh Wood Design Intelligence LLC 1037 Erikson Dr. Rexburg, ID 83440 Phone 208-359-1461 Fax 208-359-0740 Email josh@designintel.com AHJ/FM: 435-640-2075 Bryce Boyer is the Warden. https://www.summitcounty.org/561/Fire-Warden Kamas? AHJ told him Dry System needed. No Engine access in winter. Bridges will support trucks in summer. (Bridges are trailers). Volunteer Fire. Building Dept: Summit County OWNER: Works at SLC Airport Randy Sudbury (801) 557-4454 r.sudbury@hotmail.com Heather Sudbury heather.sudbury@hsc.utah.edu 2137 E Wilson Ave. SLC UT 84108 PERMIT: eg: BLD201Y-##### PROJECT STATUS: (Awarded) (Open to Bid) START DATE: PROJECT LOCATION: 9000 Weber Canyon Rd. Weber Cyn Rd Holiday Park Uinta/Cache Forest. Summit County. via Kamas out of Oakley PARCEL INFORMATION: Sales Taxable: YES Note: TU = Tilt Up TI = Tenant Improvement DESCRIPTION Occupancy R-13 Cat-2 New construction spring 2020. 4,000 SF Log cabin. Has 500gal plastic basement tank. Water from well pump only in summer. Water is shut off in winter. No heat in bldg in Winter. AHJ told him to use a dry system. Electricity supply all year-round. AND: a noti of .... MEETINGS YOU MUST/MAY ATTEND in order to BID!!!! ---------------------------------------------------------------------------------------------------------- CALL OUT B Divisions that I require an answer/bid from BY RETURN email please. the div list here will be annotated accordingly [options are: BID/NoBid] Div-10 Fire Protection Specialties REQUIRED Div-21 Fire Suppression Sprinklers etc REQUIRED Div-26 Electrical No Answer Div-28 Life Safety Fire Alarms No Answer Div-31-33 Ground No Answer Sometimes I do NOT know what divs are required. you will have to check, and advise me if you notice, & I shall update the !Notes.txt here. ---------------------------------------------------------------------------------------------------------- CALLOUT C for you to observe the PlanRoom Folders that have data. e.g.: Addenda, Plans, Pics, Docs you will need to check folders that may be added to from time to time, i won't always advise you. //====================================================================== CALLOUT Z TAKE NOTE: - Sprink Inspectors; - Hood Installer, - Hood Cleaner - Alarm Manager - Extinguisher & Cabinet Group be Advised: ALL FIRE SUPPRESSION DIVISIONS ARE SUBJECT TO: DIVISION 23 SECTION 23 05 50 - OPERATIONS & MAINTENANCE MANUALS; Identification of Pipe-Work; - Training of Maint Staff and other personel; Warranty. This is a CONDITION of the A201 Contract & Scope on ALL CONTRACTS. I don't want to hear about it! We MUST Supply/Deliver to the Customer: - Hands-on & Lecture TRAINING AND - we invite the local Fire Crew out to view the fittings and FDC & Riser Location. - We MUST Supply: - a Training Manual (Three Hard Copies) AND - Full-Size AS-BUILT drawings. (Three Hard Copies) - All Installation, Operation, Instruction & Repair Manuals for the installed equipment. - And all also cut onto a CD/DVD size disc. (Three Copies) Arun (Mr.) Compliance Manager 2016-Oct-17 //======================================================================