!Template ver: 11:47 2018-01-10 lmods: 2021-09-20 Change to Millcreek Mods: 2015-04-30 ---------------------------------------------------------------------------------------------------------- Company Invited: Fire Suppression Services (Millcreek, UT) CALLOUT A Due Date: 2022-01-11 Job:`Utah Pet Access Jobname: UPA Manager: Bradley Wardle Phone: (801) 635-9431 brad@utahpetaccess.com Manager: Trevor Sloan Phone: (801) 652-9446 trevor@utahpetaccess.com Mechanical: Architect: Self AHJ/FM: North Salt Lake OWNER: PERMIT: eg: BLD202Y-##### PROJECT STATUS: (Awarded) (Open to Bid) START DATE: PROJECT LOCATION: 175 South River Bend way, North Salt Lake, UT 84054 unit 2 PARCEL INFORMATION: Sales Taxable: YES/NO Note: TU = Tilt Up TI = Tenant Improvement DESCRIPTION Build out from initial shell. Two floors offices on each. Add to existing shell sprinklers. Riser is south end of building. Add to exisiting alarm system Add required portable extinguishers AND: a noti of .... MEETINGS YOU MUST/MAY ATTEND in order to BID!!!! ---------------------------------------------------------------------------------------------------------- CALL OUT B Divisions that I require an answer/bid from BY RETURN email please. the div list here will be annotated accordingly [options are: BID/NoBid] Div-10 Fire Protection Specialties REQUIRED Div-21 Fire Suppression Sprinklers etc REQUIRED Div-26 Electrical Done by Others Div-28 Life Safety Fire Alarms REQUIRED Div-31-33 Ground Done by Others Sometimes I do NOT know what divs are required. you will have to check, and advise me if you notice, & I shall update the !Notes.txt here. ---------------------------------------------------------------------------------------------------------- CALLOUT C for you to observe the PlanRoom Folders that have data. e.g.: Addenda, Plans, Pics, Docs you will need to check folders that may be added to from time to time, i won't always advise you. //====================================================================== CALLOUT Z TAKE NOTE: - Sprink Inspectors; - Hood Installer, - Hood Cleaner - Alarm Manager - Extinguisher & Cabinet Group be Advised: ALL FIRE SUPPRESSION DIVISIONS ARE SUBJECT TO: DIVISION 23 SECTION 23 05 50 - OPERATIONS & MAINTENANCE MANUALS; Identification of Pipe-Work; - Training of Maint Staff and other personel; Warranty. This is a CONDITION of the A201 Contract & Scope on ALL CONTRACTS. I don't want to hear about it! We MUST Supply/Deliver to the Customer: - Hands-on & Lecture TRAINING AND - we invite the local Fire Crew out to view the fittings and FDC & Riser Location. - We MUST Supply: - a Training Manual (Three Hard Copies) AND - Full-Size AS-BUILT drawings. (Three Hard Copies) - All Installation, Operation, Instruction & Repair Manuals for the installed equipment. - And all also cut onto a CD/DVD size disc. (Three Copies) Arun (Mr.) Compliance Manager 2016-Oct-17 //======================================================================