!Template ver: 11:47 2018-01-10 ---------------------------------------------------------------------------------------------------------- Company Invited: Fire Suppression Services (Salt Lake City, UT) CALLOUT A Due Date: Nov-01 2020 CONTRACTOR: Milestone Projects. 1883 E 9400 S Sandy. 84093 Manager: David E. Kavanagh Cell: (801) 573-7844 or Office: Julie Banks julie@utahmilestones.com Office: (801) 944-8802 Site Super: Morgan Baker (385) 242-2540 Facilities Manager: Jon Murray (801) 942-1751 jon@lacaille.com Mechanical: ENSIGN 45 W 10000 S #500. Sandy 84070 Dennis Jenkins (801) 255-0529 Project# 4978D (Drawing C-100) Architect: Lu'na 175 W 200 E #2020 SLC UT 84101 801 350-2046 AHJ/FM: Unified Fire Auth. S Gray WATER: Lennie Chanthaphuang Lennie@Sandy.Utah.gov C 801 568-7293. O 801 706-9026 Or (801) 568-7100 (Ask for Lennie (He is Thai PU Engineer) PERMIT: eg: BLD20yy-TBD OWNER: HOLLADAY 2550 LLC. Kevin Gates 9565 S. Wasatch Blvd PROJECT STATUS: (Awarded) (Open to Bid) START DATE: ASAP PROJECT LOCATION: La Caille 9565 South Wasatch Blvd. Sandy City UT 84092 (unincorporated Salt Lake County) Has a Silent Knight SK-2 Panel (Installed by Talmadge Gray) 2012 PARCEL INFORMATION: https://parcels.utah.gov/#/location/-12445131.291748136,4949895.535229622,4513.988705 227-064 Building is on UNINCORPORATED County land at 151-039 Parcel: 28121510390000 Parcel 28121510390000 Legal description LOT 3, THE LA CAILLE SUB. 7052-1873 7081-0001 9161-8747 Sales Taxable: YES Note: TI = Tenant Improvement DESCRIPTION AND: a noti of .... MEETINGS YOU MUST/MAY ATTEND in order to BID!!!! ---------------------------------------------------------------------------------------------------------- met on Nov-20 & 25 for field checks, 11:52 AM 12/3/2020 Calling DEK to see if Randal Parker can be there 09:30 to tomorrow 12:06 PM 12/3/2020 Advised Morgan Baker 12:06 PM 12/3/2020 Calling Jon (FM) 12:02 PM 12/4/2020 Spoke w/Scott Adams WC-3: Craig Hansen is just finishing up the Review. CALL OUT B Divisions that I require an answer/bid from BY RETURN email please. the div list here will be annotated accordingly [options are: BID/NoBid] Div-21 Fire Suppression Sprinklers etc REQUIRED Div-28 Life Safety Fire Alarms SK-2 2-zone Conventional panel POTSx2 Sprinks only (Tal Gray) Div-31-33 Ground No Answer Sometimes I do NOT know what divs are required. you will have to check, and advise me if you notice, & I shall update the !Notes.txt here. ---------------------------------------------------------------------------------------------------------- CALLOUT C for you to observe the PlanRoom Folders that have data. e.g.: Addenda, Plans, Pics, Docs you will need to check folders that may be added to from time to time, i won't always advise you. //====================================================================== CALLOUT Z TAKE NOTE: - Sprink Inspectors; - Hood Installer, - Hood Cleaner - Alarm Manager - Extinguisher & Cabinet Group be Advised: ALL FIRE SUPPRESSION DIVISIONS ARE SUBJECT TO: DIVISION 23 SECTION 23 05 50 - OPERATIONS & MAINTENANCE MANUALS; Identification of Pipe-Work; - Training of Maint Staff and other personel; Warranty. This is a CONDITION of the A201 Contract & Scope on ALL CONTRACTS. I don't want to hear about it! We MUST Supply/Deliver to the Customer: - Hands-on & Lecture TRAINING AND - we invite the local Fire Crew out to view the fittings and FDC & Riser Location. - We MUST Supply: - a Training Manual (Three Hard Copies) AND - Full-Size AS-BUILT drawings. (Three Hard Copies) - All Installation, Operation, Instruction & Repair Manuals for the installed equipment. - And all also cut onto a CD/DVD size disc. (Three Copies) Arun (Mr.) Compliance Manager 2016-Oct-17 //======================================================================